ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
SNA5000A Series : เวกเตอร์เน็ตเวิร์คอนาไลเซอร์, ช่วงความถี่ 9 kHz ถึง 8.5 GHz, 4 ช่องสัญญาณ, จอสัมผัสขนาด 12.1 นิ้ว
ข้อมูลสินค้า
-
รหัสสินค้า
SNA5014A/SNA5002A/SNA5004A/SNA5012A
-
เข้าชม
1,769 ครั้ง
ยี่ห้อ
SIGLENT
รุ่น
SNA5014A/SNA5002A/SNA5004A/SNA5012A
-
แก้ไขล่าสุดเมื่อ
22/07/2021 13:30
-
รายละเอียดสินค้า
SNA5000A Series : เวกเตอร์เน็ตเวิร์คอนาไลเซอร์, ช่วงความถี่ 9 kHz ถึง 8.5 GHz, 4 ช่องสัญญาณ, จอสัมผัสขนาด 12.1 นิ้ว
General Description The SIGLENT SNA5000A series of Vector Network Analyzers have a frequency range of 9 kHz to 8.5 GHz, which support 2/4-ports scattering-parameter, differential-parameter, and time-domain parameter measurements. The SNA5000A series of VNAs are effective instrumentation for determining the Q-factor, bandwidth and insertion loss of a filter, They feature impedance conversion, movement of measurement plane, limit testing, ripple test, fixture simulation and adapter removal/insertion adjustments. The VNAs have five sweep types: Linear-Frequency mode, Log-Frequency mode, Power-Sweep mode, CW-Time mode and Segment-Sweep mode. The SNA5000A series VNAs also support scattering-parameter correction of SOLT, SOLR, TRL, Response and Enhanced Response for increased flexibility in R&D and manufacturing applications. Features ▪ Frequency range: 9 kHz - 8.5 GHz ▪ Frequency resolution: 1 Hz ▪ Level resolution: 0.05 dB ▪ Range of IFBW: 10 Hz~3 MHz ▪ Setting range of output level: -55 dBm ~ +10 dBm ▪ Dynamic range: 125 dB ▪ Types of calibration: Response calibration, Enhanced Response calibration, Full-one port calibration, Full-two port calibration, Full-three port calibration, Full-four port ▪ Types of measurement: Scattering-parameter measurement, differential-parameter measurement, receiver measurement, time-domain parameter analysis, limit test, ripple test, impedance conversion, fixture simulation, adapter removal/insertion ▪ Support Bias-Tees ▪ Interface: LAN, USB Device, USB Host(USB-GPIB) ▪ Remote control: SCPI/Labview/IVI based on USB-TMC/VXI-11/Socket/Telnet/WebServer 12.1-inch touch screen ▪ Video output: HDMI Models and key specifications Design Features Multi-window display: Multi-format display: Display and compare memory and current data: Display data hold: Impedance conversion: Equation Editor: Port Extensions: Embedding and De-Embedding: Time-Domain analysis: Enhanced Time-Domain analysis(TDR) Definitions Specifications are valid under the following conditions: The instrument is within the calibration period, has been stored between 0 and 40℃ for at least 2 hours before use, and has been powered on and warmed up for at least 90 minutes. The specifications include the measurement uncertainty unless otherwise noted. Specifications: All products are guaranteed to meet published specifications at room temperature approximately 25℃), unless otherwise noted. Typical: Performance deemed typical implies that 80 percent of the measurement results will meet the ypical published performance with a 95th percentile confidence level at room temperature (approximately 25℃). Typical performance is not warranted and does not include measurement uncertainty. Specifications Dynamic range Corrected system performance with calibration kit User correction: On, system correction: On; Corrected system performance with Keysight 85052D 3.5mm calibration kit, isolation calibration performed.IFBW is 10 Hz,no averaging applied to data, environmental temperature is 25℃ (± 5℃), with<1℃ deviation from calibration temperature.